Performance of 5-𝜇mPIN diamond diodes as thermal neutron detectors

Diamond PIN diodes with an approximately 5-𝜇m thick i-layer and coated with a thin boron nitride (BN) layer have been tested with a thermal neutron beam. For a flux of 4.4 °¡ 106 n/s/cm2, count rates were on the order of 30–100 counts per second depending on the thickness of the BN neutron converter layer. Pulse height spectra showed features associated with 𝛼 and 7Li fission products consistent with the thickness of the BN layer. An irradiation test with a 1 MeV neutron equivalent fluence of 1015 n/cm2 showed no significant alteration in the count rate of the tested detector.


Fig. 3. Detector mount. The detector frames made out of printed circuit boards with